About: Neutron research facility is a research topic. Over the lifetime, 89 publications have been published within this topic receiving 1157 citations.
TL;DR: The CNDP instrument is described, the neutron depth profiling technique is illustrated, the first nondestructive measurements of 17O profiles are permitted, and a separate bibliography of NDP publications is given.
Abstract: The Cold Neutron Depth Profiling (CNDP) instrument at the NIST Cold Neutron Research Facility (CNRF) is now operational. The neutron beam originates from a 16 L D2O ice cold source and passes through a filter of 135 mm of single crystal sapphire. The neutron energy spectrum may be described by a 65 K Maxwellian distribution. The sample chamber configuration allows for remote controlled scanning of 150 x 150 mm sample areas including the varying of both sample and detector angle. The improved sensitivity over the current thermal depth profiling instrument has permitted the first nondestructive measurements of (17)O profiles. The paper describes the CNDP instrument, illustrates the neutron depth profiling (NDP) technique with examples, and gives a separate bibliography of NDP publications.
TL;DR: The time-of-flight technique is employed in two of the instruments at the NIST Cold Neutron Research Facility and may be used in a variety of types of experiments such as studies of vibrational and magnetic excitations, tunneling spectroscopy, and quasielastic scattering studies of diffusional behavior.
Abstract: The time-of-flight technique is employed in two of the instruments at the NIST Cold Neutron Research Facility (CNRF). A pulsed monochromatic beam strikes the sample, and the energies of scattered neutrons are determined from their times-of-flight to an array of detectors. The time-of-flight method may be used in a variety of types of experiments such as studies of vibrational and magnetic excitations, tunneling spectroscopy, and quasielastic scattering studies of diffusional behavior; several examples of experiments are discussed. The authors also present brief descriptions of the CNRF time-of-flight instruments, including their modi operandi and some of their more pertinent parameters and performance characteristics.
TL;DR: The cold neutron capture prompt γ-ray activation analysis (CNPGAA) spectrometer located in the Cold Neutron Research Facility (CNRF) at NIST has proven useful for the analysis of hydrogen and other elements in a wide variety of materials as mentioned in this paper.
Abstract: The cold neutron capture prompt γ-ray activation analysis (CNPGAA) spectrometer located in the Cold Neutron Research Facility (CNRF) at NIST has proven useful for the analysis of hydrogen and other elements in a wide variety of materials. Modifications of the instrument and the CNRF have resulted in improved measurement capabilities for PGAA. The addition of an atmosphere-controlled sample chamber and Compton suppression have reduced γ-ray background and increased signal-to-noise ratio. More recent revisions are expected to yield still further improvement in analytical capabilities. Replacement of the D2O ice cold source with a liquid H2 moderator is expected to yield a 5–10 fold increase in neutron capture rate, and improved neutron and γ-ray shielding will result in further reduction of the background. Other modifications to the instrument allow easier sample mounting and more precise positioning of samples in the neutron beam. Significant improvements in detection limits and analytical accuracy are expected.
TL;DR: The present article provides an introduction to the Cold Neutron Research Facility, and to other articles in the current issue that give more details on some of the research opportunities that the facility will bring to NIST.
Abstract: The Cold Neutron Research Facility (CNRF) at the National Institute of Standards and Technology (NIST) Research Reactor (NBSR) is now coming on line, with the first seven experimental stations operational, and more stations scheduled to be installed during 1992. The present article provides an introduction to the facility, and to other articles in the current issue that give more details on some of the research opportunities that the facility will bring to NIST.
TL;DR: An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor as mentioned in this paper.
Abstract: An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor. The neutron fluence rate (thermal equivalent) is 1.5·108 n ·cm−2·s−1, with negligible fast neutrons and gamma-rays. With compact geometry and hydrogen-free construction, the sensitivity is sevenfold better than an existing thermal instrument. Hydrogen background is thirtyfold lower.