TL;DR: This work automates routine small-molecule structure determination starting from single-crystal reflection data, the Laue group and a reasonable guess as to which elements might be present.
Abstract: The new computer program SHELXT employs a novel dual-space algorithm to solve the phase problem for single-crystal reflection data expanded to the space group P1. Missing data are taken into account and the resolution extended if necessary. All space groups in the specified Laue group are tested to find which are consistent with the P1 phases. After applying the resulting origin shifts and space-group symmetry, the solutions are subject to further dual-space recycling followed by a peak search and summation of the electron density around each peak. Elements are assigned to give the best fit to the integrated peak densities and if necessary additional elements are considered. An isotropic refinement is followed for non-centrosymmetric space groups by the calculation of a Flack parameter and, if appropriate, inversion of the structure. The structure is assembled to maximize its connectivity and centred optimally in the unit cell. SHELXT has already solved many thousand structures with a high success rate, and is optimized for multiprocessor computers. It is, however, unsuitable for severely disordered and twinned structures because it is based on the assumption that the structure consists of atoms.
TL;DR: In this article, the behaviour of the Rogers's η parameter for enantiomorph-polarity estimation is examined theoretically and experimentally on simulated intensity data for seven well-assorted compounds.
Abstract: The behaviour of Rogers's η parameter for enantiomorph-polarity estimation is examined theoretically and experimentally on simulated intensity data for seven well-assorted compounds. An alternative parameter x, based on incoherent scattering from twin components related by a centre of symmetry, is also considered. It is found that both parameters are very well adapted to implementation in a least-squares program and converge well. The η parameter can give false and over-precise indications of chirality-polarity for structures which are nearly centrosymmetric, whereas the x parameter does not have this fault and converges more rapidly than η.
TL;DR: Differences and quotients can be defined using Friedel pairs of reflections and applied in refinement to enable absolute structure to be determined precisely even for light atom crystal structures.
Abstract: Several methods for absolute structure refinement were tested using single-crystal X-ray diffraction data collected using Cu Kα radiation for 23 crystals with no element heavier than oxygen: conventional refinement using an inversion twin model, estimation using intensity quotients in SHELXL2012, estimation using Bayesian methods in PLATON, estimation using restraints consisting of numerical intensity differences in CRYSTALS and estimation using differences and quotients in TOPAS-Academic where both quantities were coded in terms of other structural parameters and implemented as restraints. The conventional refinement approach yielded accurate values of the Flack parameter, but with standard uncertainties ranging from 0.15 to 0.77. The other methods also yielded accurate values of the Flack parameter, but with much higher precision. Absolute structure was established in all cases, even for a hydrocarbon. The procedures in which restraints are coded explicitly in terms of other structural parameters enable the Flack parameter to correlate with these other parameters, so that it is determined along with those parameters during refinement.
TL;DR: In this article, practical and numerical information for undertaking and evaluating absolute structure and configuration determinations is provided for macromolecular structures, the dangers of polar-dispersion errors, Euclidean normalizers of space groups, detection and reporting of molecular symmetry, enantiopurity and optical activity in solution.
Abstract: Detailed practical and numerical information is provided for undertaking and evaluating absolute-structure and absolute-configuration determinations. The interpretation of numerical values of x, the Flack [Acta Cryst. (1983), A39, 876–881] parameter, and its standard uncertainty u are explained in terms of the inversion-distinguishing power. Moreover, the conditions to obtain reliable values of x(u) are detailed. Further explanatory material is provided on the use of right-handed axes, valid intensity data, the application to macromolecular structures, the dangers of polar-dispersion errors, Euclidean normalizers of space groups, the detection and reporting of molecular symmetry, enantiopurity and optical activity in solution. New CIF data names are introduced.
TL;DR: Important experimental and algorithmic details of the current methods used for absolute-structure determination are provided and attention is given to the analysis of absolute structure and absolute configuration in twinned crystals.
Abstract: Fundamental notions concerning absolute structure and absolute configuration, and their determination from single-crystal diffraction measurements, are presented and reviewed. A glossary of terms with definitions useful in this field is provided. For absolute structure and its determination, the separate but interacting influences of the structure and the inversion-distinguishing power of an X-ray diffraction experiment with dispersive scatterers are examined. Important experimental and algorithmic details of the current methods used for absolute-structure determination are provided. Characterization of crystals for absolute-structure determination and of molecules for absolute-configuration determination are treated. Attention is given to the analysis of absolute structure and absolute configuration in twinned crystals.