TL;DR: A carbon beam of 80 keV/microm in the spread-out Bragg peak was found to be equivalent in biological responses to the neutron beam that is produced at cyclotron facility in National Institute Radiological Sciences (NIRS) by bombarding 30-MeV deuteron beam on beryllium target.
TL;DR: Results of clinical phase I-II trials provide evidence that carbon-ion radiotherapy might be beneficial in several tumor entities, and the progress in heavy-ion therapy is reviewed, including physical and technical developments, radiobiological studiesmore and models, as well as radiooncological studies.
Abstract: High-energy beams of charged nuclear particles (protons and heavier ions) offer significant advantages for the treatment of deep-seated local tumors in comparison to conventional megavolt photon therapy. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum (Bragg peak) near the end of range with a sharp fall-off at the distal edge. Taking full advantage of the well-defined range and the small lateral beam spread, modern scanning beam systems allow delivery of the dose with millimeter precision. In addition, projectiles heavier than protons such as carbon ions exhibit an enhanced biological effectiveness in the Bragg peak region caused by the dense ionization of individual particle tracks resulting in reduced cellular repair. This makes them particularly attractive for the treatment of radio-resistant tumors localized near organs at risk. While tumor therapy with protons is a well-established treatment modality with more than 60 000 patients treated worldwide, the application of heavy ions is so far restricted to a few facilities only. Nevertheless, results of clinical phase I-II trials provide evidence that carbon-ion radiotherapy might be beneficial in several tumor entities. This article reviews the progress in heavy-ion therapy, including physical and technical developments, radiobiological studiesmore » and models, as well as radiooncological studies. As a result of the promising clinical results obtained with carbon-ion beams in the past ten years at the Heavy Ion Medical Accelerator facility (Japan) and in a pilot project at GSI Darmstadt (Germany), the plans for new clinical centers for heavy-ion or combined proton and heavy-ion therapy have recently received a substantial boost.« less
TL;DR: The method of measuring and inverting diffraction patterns from nanocrystals represents a vital step towards the ultimate goal of atomic resolution single-molecule imaging that is a prominent justification for development of X-ray free-electron lasers.
Abstract: Synchrotron X-ray radiation, produced by electron accelerators at central facilities, can now be produced in extremely narrow coherent beams. When these X-rays illuminate a crystal of nanometre dimensions a diffraction pattern emerges that is highly resolved. This provides a powerful new tool for structural analysis, as the fine features of the diffraction pattern can be interpreted in terms of sub-atomic distortions within the crystal attributable to its contact with an external support. Coherent X-ray diffraction patterns derived from third-generation synchrotron radiation sources can lead to quantitative three-dimensional imaging of lattice strain on the nanometre scale. Coherent X-ray diffraction imaging is a rapidly advancing form of microscopy: diffraction patterns, measured using the latest third-generation synchrotron radiation sources, can be inverted to obtain full three-dimensional images of the interior density within nanocrystals1,2,3. Diffraction from an ideal crystal lattice results in an identical copy of this continuous diffraction pattern at every Bragg peak. This symmetry is broken by the presence of strain fields, which arise from the epitaxial contact forces that are inevitable whenever nanocrystals are prepared on a substrate4. When strain is present, the diffraction copies at different Bragg peaks are no longer identical and contain additional information, appearing as broken local inversion symmetry about each Bragg point. Here we show that one such pattern can nevertheless be inverted to obtain a ‘complex’ crystal density, whose phase encodes a projection of the lattice deformation. A lead nanocrystal was crystallized in ultrahigh vacuum from a droplet on a silica substrate and equilibrated close to its melting point. A three-dimensional image of the density, obtained by inversion of the coherent X-ray diffraction, shows the expected facetted morphology, but in addition reveals a real-space phase that is consistent with the three-dimensional evolution of a deformation field arising from interfacial contact forces. Quantitative three-dimensional imaging of lattice strain on the nanometre scale will have profound consequences for our fundamental understanding of grain interactions and defects in crystalline materials4. Our method of measuring and inverting diffraction patterns from nanocrystals represents a vital step towards the ultimate goal of atomic resolution single-molecule imaging that is a prominent justification for development of X-ray free-electron lasers5,6,7.
TL;DR: It is concluded that the 3D method provides the greatest flexibility for constructing conformal doses in challenging situations, but that when large numbers of beam ports are available, little advantage may be gained from the additional modulation of intensity in depth.
Abstract: The characteristic Bragg peak of protons or heavy ions provides a good localization of dose in three dimensions. Through their ability to deliver laterally and distally shaped homogenous fields, protons have been shown to be a precise and practical method for delivering highly conformal radiotherapy. However, in an analogous manner to intensity modulation for photons, protons can be used to construct dose distributions through the application of many individually inhomogeneous fields, but with the localization of dose in the Bragg peak providing the possibility of modulating intensity within each field in two or three dimensions. We describe four different methods of intensity modulation for protons and describe how these have been implemented in an existing proton planning system. As a preliminary evaluation of the efficacy of these methods, each has been applied to an example case using a variety of field combinations. Dose-volume histogram analysis of the resulting dose distributions shows that when large numbers of fields are used, all techniques exhibit both good target homogeneity and sparing of neighbouring critical structures, with little difference between the four techniques being discerned. As the number of fields is decreased, however, only a full 3D modulation of individual Bragg peaks can preserve both target coverage and sparing of normal tissues. We conclude that the 3D method provides the greatest flexibility for constructing conformal doses in challenging situations, but that when large numbers of beam ports are available, little advantage may be gained from the additional modulation of intensity in depth.
TL;DR: In the scheme proposed, a beam of fast ions accelerated by a laser pulse can be integrated in the installations intended for proton therapy, ensuring that the irradiation of the surrounding healthy tissues and organs is minimal.
Abstract: The feasibility of using laser plasma as a source of high-energy ions for the purposes of proton therapy is discussed The proposal is based on the efficient ion acceleration observed in recent laboratory and numerical experiments on the interaction of high-power laser radiation with gaseous and solid targets The specific dependence of proton energy losses in biological tissues (the Bragg peak) promotes the solution of one of the main problems of radiation therapy, namely, the irradiation of a malignant tumor with a sufficiently strong and homogeneous dose, ensuring that the irradiation of the surrounding healthy tissues and organs is minimal In the scheme proposed, a beam of fast ions accelerated by a laser pulse can be integrated in the installations intended for proton therapy