Software algorithm and hardware design for real-time implementation of new spectral estimator
TL;DR: The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra.
read more
Abstract: Background: Real-time spectral analyzers can be difficult to implement for PC computer-based systems because of the potential for high computational cost, and algorithm complexity. In this work a new spectral estimator (NSE) is developed for real-time analysis, and compared with the discrete Fourier transform (DFT). Method: Clinical data in the form of 216 fractionated atrial electrogram sequences were used as inputs. The sample rate for acquisition was 977 Hz, or approximately 1 millisecond between digital samples. Real-time NSE power spectra were generated for 16,384 consecutive data points. The same data sequences were used for spectral calculation using a radix-2 implementation of the DFT. The NSE algorithm was also developed for implementation as a real-time spectral analyzer electronic circuit board. Results: The average interval for a single real-time spectral calculation in software was 3.29 μs for NSE versus 504.5 μs for DFT. Thus for real-time spectral analysis, the NSE algorithm is approximately 150× faster than the DFT. Over a 1 millisecond sampling period, the NSE algorithm had the capability to spectrally analyze a maximum of 303 data channels, while the DFT algorithm could only analyze a single channel. Moreover, for the 8 second sequences, the NSE spectral resolution in the 3-12 Hz range was 0.037 Hz while the DFT spectral resolution was only 0.122 Hz. The NSE was also found to be implementable as a standalone spectral analyzer board using approximately 26 integrated circuits at a cost of approximately $500. The software files used for analysis are included as a supplement, please see the Additional files 1 and 2. Conclusions: The NSE real-time algorithm has low computational cost and complexity, and is implementable in both software and hardware for 1 millisecond updates of multichannel spectra. The algorithm may be helpful to guide radiofrequency catheter ablation in real time.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Three-dimensional dominant frequency mapping using autoregressive spectral analysis of atrial electrograms of patients in persistent atrial fibrillation
Joao L Salinet,Nicholas G. D. Masca,Peter J. Stafford,Peter J. Stafford,G. André Ng,G. André Ng,Fernando S. Schlindwein,Fernando S. Schlindwein +7 more
TL;DR: The feasibility of using AR spectral estimation methods for producing 3D DF maps and characterised their differences to the maps produced using the FFT technique are demonstrated, offering an alternative approach for3D DF computation in human persAF studies.
Differences in continuous spectra of fractionated electrograms in paroxysmal versus persistent atrial fibrillation
TL;DR: The results suggest that atrial electrical activation becomes more stable and focused at a narrow frequency range in persistent as compared to paroxysmal AF.
3
References
•Book
Numerical Recipes in FORTRAN
William T. Vetterling,Saul A. Teukolsky,William H. Press,Brian P. Flannery +3 more
- 26 Feb 1988
TL;DR: The Diskette v 2.04, 3.5'' (720k) for IBM PC, PS/2 and compatibles [DOS] Reference Record created on 2004-09-07, modified on 2016-08-08.
10.2K
A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate
Koonlawee Nademanee,John McKenzie,Erol M. Kosar,Mark Schwab,Buncha Sunsaneewitayakul,Thaveekiat Vasavakul,Chotikorn Khunnawat,Tachapong Ngarmukos +7 more
TL;DR: Testing the hypothesis that complex fractionated electrograms recorded during atrial fibrillation could be used as target sites for catheter ablation of AF found areas with CFAEs represent a defined electrophysiologic substrate and are ideal target Sites for ablations to eliminate AF and maintain normal sinus rhythm.
2.2K
Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans
Prashanthan Sanders,Omer Berenfeld,Mélèze Hocini,Pierre Jaïs,Ravi Vaidyanathan,Li Fern Hsu,S. Garrigue,Yoshihide Takahashi,Martin Rotter,Frédéric Sacher,C. Scavee,Robert Ploutz-Snyder,José Jalife,Michel Haïssaguerre +13 more
TL;DR: Spectral analysis and frequency mapping identify localized sites of high-frequency activity during atrial fibrillation in humans with different distributions in paroxysmal and permanent AF, indicating their role in the maintenance of AF.
922
Clinical Mapping Approach To Diagnose Electrical Rotors and Focal Impulse Sources for Human Atrial Fibrillation
TL;DR: A clinical computational mapping approach is developed, guided by human atrial tissue physiology, to reveal sources of human AF.
Non-invasive assessment of the atrial cycle length during atrial fibrillation in man: introducing, validating and illustrating a new ECG method
Magnus Holm,Steen Pehrson,Max Ingemansson,Leif Sörnmo,Rolf Johansson,Lennart Sandhall,Max Sunemark,Birgit Smideberg,Christian Olsson,S. Bertil Olsson +9 more
TL;DR: A new non-invasive method, named 'Frequency Analysis of Fibrillatory ECG' (FAF-ECG), is capable of assessing both the magnitude and the dynamics of the atrial fibrillation cycle length in man.
298