Journal Article10.4135/9781412961288.n327
Precision
TL;DR: The upgraded Inner Tracker (ITk) detector modules undergo rigorous QC and QA procedures, including optical metrology surveys on key components such as the PCB, active sensor, and power circuit. These surveys ensure mechanical precision and identify faulty or biased measurements. Electrical components are also measured for position and height, ensuring assembly meets design specifications.
read more
Abstract: As part of the High Luminosity LHC (HL-LHC) programme, the ATLAS pixel and strip detector, and transition-radiation tracker, will be upgraded to an all-silicon Inner Tracker (ITk). To ensure each detector module comprising the upgraded detector is produced at a high standard, modules undergo rigorous Quality Control (QC) and Quality Assurance (QA). Several standard QC measures are performed on assembled modules; such measures include: electrical testing, pull testing, precision gluing, and high resolution visual inspection. This work presents the optical metrology surveys on key components of the module such as: the printed circuit board (PCB) containing the readout electronics, the active sensor, and power circuit. Each assembled module has the sensor bowing, and height and position of electronic components examined. These surveys ensure mechanical precision during detector assembly. Measurements are made with a micrometre precision optical Coordinate Measuring Machine (CMM). To ensure high quality modules, the sensor surface is inspected for uniformity. Sensor bowing is measured using, at minimum, an 11 x 11 uniform grid point scan at 1 cm pitch. Bowing is defined to be the difference in height between the lowest and highest point on the sensor; concave tolerance is 150 um and convex tolerance is 50 um. Hence, employing the most accurate optical measurements, using the optimal focussing device and settings, is crucial. Custom written CMM software achieves this scan with precision and the data is then cleaned and analysed. Faulty, biased, or irrelevant measurements are filtered, or corrected, and properties of the sensor surface are identified; pass / fail requirements are then imposed. In addition, electrical components of the detector module undergo position measurements and height measurements. The former measures the positions of fiducial markers on the PCB and power circuit, ensuring assembly satisfies the sub 100 um design specifications. The latter measures the height of several electronic components on the PCB and power circuit, ensuring precision for both the individual components and the module as a whole. CMM scripts for navigating to these components for various module geometries have been produced, likewise for the data
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps