Journal Article10.1088/1755-1315/15/7/072010
Numerical simulation on dimension decrease for annular casing of one centrifugal boiler circulation pump
Yi Fan,Z G Zuo,Sheng Hua Liu,Yuen Wu,Yujun Sha +4 more
- 26 Nov 2012
- Vol. 15, Iss: 7, pp 072010
1
TL;DR: In this paper, a numerical simulation research is developed on dimension decrease for annular casing of a pump with a specific speed equaling to 189, which aims at finding an appropriately smaller dimension of the casing while hydraulic performance and strength performance will hardly be changed according to the requirements of the cooperative company.
read more
Abstract: Primary formulation derivation indicates that the dimension of one existing centrifugal boiler circulation pump casing is too large. As great manufacture cost can be saved by dimension decrease, a numerical simulation research is developed in this paper on dimension decrease for annular casing of this pump with a specific speed equaling to 189, which aims at finding an appropriately smaller dimension of the casing while hydraulic performance and strength performance will hardly be changed according to the requirements of the cooperative company. The research object is one existing centrifugal pump with a diffuser and a semi-spherical annular casing, working as the boiler circulation pump for (ultra) supercritical units in power plants. Dimension decrease, the modification method, is achieved by decreasing the existing casing's internal radius (marked as Ri0) while keeping the wall thickness. The research analysis is based on primary formulation derivation, CFD (Computational Fluid Dynamics) simulation and FEM (Finite Element Method) simulation. Primary formulation derivation estimates that a design casing's internal radius should be less than 0.75 Ri0. CFD analysis indicates that smaller casing with 0.75 Ri0 has a worse hydraulic performance when working at large flow rates and a better hydraulic performance when working at small flow rates. In consideration of hydraulic performance and dimension decrease, an appropriate casing's internal radius is determined, which equals to 0.875 Ri0. FEM analysis then confirms that modified pump casing has nearly the same strength performance as the existing pump casing. It is concluded that dimension decrease can be an economical method as well as a practical method for large pumps in engineering fields.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Research on pressure fluctuation in impeller and guide vane of boiler water circulating pump
Zhao Fei,Duan Xiaohui,Xia Bin,Bai Yuxing +3 more
- 01 Sep 2017
TL;DR: In this article, the pressure fluctuation of impeller and guide vane in boiler water circulating pump was calculated and analyzed by software ANSYS-CFX, and the results showed that with an increase of the flow rate, the periodicity of pressure fluctuations at monitoring points in the impeller was more and more obvious and the fluctuation amplitude decreases gradually.
1
References
•Book
Centrifugal and Axial Flow Pumps: Theory, Design, and Application
Alexey J. Stepanoff
- 12 Mar 1991
TL;DR: Project deeharga.com as discussed by the authors is a free e-book platform with many thousands of free and legal books to download in PDF as well as many other formats, it is known to be world's largest free Books platform.
309