Journal Article10.1016/S0168-9002(02)02045-4
Mythen detector system
Bernd Schmitt,Ch. Brönnimann,E. F. Eikenberry,Fabia Gozzo,C Hörmann,Roland Horisberger,Bruce D. Patterson +6 more
209
TL;DR: In this paper, the Mythen detector (Microstrip system for time-resolved experiments) has been built for the powder diffraction Station of the Material Science beamline at the Swiss Light Source to meet these requirements.
read more
Abstract: Time-resolved experiments in powder diffraction are limited by the long time required to record spectra with current detectors. A major improvement can be made by using a massively parallel X-ray detection system together with a fast read out. The Mythen detector (Microstrip system for time-resolved experiments) has been built for the Powder Diffraction Station of the Material Science beamline at the Swiss Light Source to meet these requirements. The specifically developed read out chip (Mythen chip), the detector system and first measurements are shown.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Beamline I11 at Diamond: a new instrument for high resolution powder diffraction.
Stephen P. Thompson,Julia E. Parker,Jonathan Potter,T. P. Hill,Adrian Birt,Tom M. Cobb,F. Yuan,C. C. Tang +7 more
TL;DR: The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented and high resolution Powder diffraction data from standard reference materials of Si, alpha-quartz, and LaB6 are used to characterize instrumental performance.
349
High-throughput powder diffraction measurement system consisting of multiple MYTHEN detectors at beamline BL02B2 of SPring-8
Shogo Kawaguchi,Michitaka Takemoto,K. Osaka,Eiji Nishibori,Chikako Moriyoshi,Yoshiki Kubota,Yoshihiro Kuroiwa,Kunihisa Sugimoto +7 more
TL;DR: A user-friendly automatic powder diffraction measurement system for Debye-Scherrer geometry using a capillary sample at beamline BL02B2 of SPring-8 and introduced two measurement modes in the MYTHEN system and developed new attachments for the sample environment such as a gas handling system.
300
Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging
Rafael Ballabriga,J. Alozy,M. Campbell,Erik Fröjdh,Erik H.M. Heijne,Erik H.M. Heijne,T Koenig,X. Llopart,J Marchal,David Pennicard,Tuomas Poikela,Lukas Tlustos,P. Valerio,W. Wong,Marcus Zuber +14 more
TL;DR: In this paper, the authors review the state of the art in semiconductor-detector readout ASICs for spectroscopic X-ray imaging with emphasis on hybrid pixel detector technology.
Everything SAXS: small-angle scattering pattern collection and correction
TL;DR: In this article, a comprehensive overview of all data corrections, to aid the small-angle scatterer to decide which are relevant for their measurement and how these corrections are performed.
199
Field-induced phase transition in Bi1/2Na1/2TiO3- based lead-free piezoelectric ceramics
Manuel Hinterstein,Manuel Hinterstein,Michael Knapp,Markus Hölzel,Wook Jo,Antonio Cervellino,Helmut Ehrenberg,Hartmut Fuess +7 more
TL;DR: The origin of the electric field-induced strain in polycrystalline ceramic 0.92Bi 1/2Na1/2TiO3 was investigated using in situ high-resolution X-ray and neutron diffraction techniques in this article, where the polarization values for the tetragonal and rhombohedral phases were calculated based on the structural information from Rietveld refinements.
References
PILATUS: a two-dimensional X-ray detector for macromolecular crystallography
E.F. Eikenberry,Ch. Brönnimann,G. Hülsen,Hidenori Toyokawa,Roland Horisberger,Bernd Schmitt,Clemens Schulze-Briese,T Tomizaki +7 more
TL;DR: A large quantum-limited area X-ray detector for protein crystallography is under development at the Swiss Light Source (SLS) as mentioned in this paper, where a three-module prototype with 1120 � 157 pixels covering an active area of 24:3 � 3: 4c m 2 has been tested.
A pixel read-out chip for the PILATUS project
Ch. Brönnimann,R. Baur,E.F. Eikenberry,S. Kohout,M. Lindner,Bernd Schmitt,Roland Horisberger +6 more
TL;DR: The PILATUS project as mentioned in this paper is a hybrid pixel system with a size of 40×40 cm 2 having 2000×2000 pixels, which will be operated in single photon counting mode for 12-keV X-rays.
64
An area efficient 128 channel counter chip
TL;DR: In this paper, a shift register of N bit length with a single exclusive-OR gate to generate periodically 2 N − 1 different states is presented, where each state is directly related to the number of clock pulses received.
•Book
Fundamentals of Crystallography
Carmelo Giacovazzo
- 22 Oct 1992
TL;DR: A comprehensive and accessible overview of modern crystallography can be found in this article, which is intended for undergraduates in physics and chemistry departments, researchers in crystallography, chemistry, solid state physics, materials science, mineralogy, molecular biology, and mathematics.