Journal Article10.1109/RBME.2019.2931587
Local Pulse Wave Velocity: Theory, Methods, Advancements, and Clinical Applications
139
TL;DR: This paper enumerates all major local PWV measurement methods while pinpointing their salient methodological considerations and emphasizing the necessity of global standardization.
read more
Abstract: Local pulse wave velocity (PWV) is evolving as one of the important determinants of arterial hemodynamics, localized vessel stiffening associated with several pathologies, and a host of other cardiovascular events. Although PWV was introduced over a century ago, only in recent decades, due to various technological advancements, has emphasis been directed toward its measurement from a single arterial section or from piecewise segments of a target arterial section. This emerging worldwide trend in the exploration of instrumental solutions for local PWV measurement has produced several invasive and noninvasive methods. As of yet, however, a univocal opinion on the ideal measurement method has not emerged. Neither have there been extensive comparative studies on the accuracy of the available methods. Recognizing this reality, makes apparent the need to establish guideline-recommended standards for the measurement methods and reference values, without which clinical application cannot be pursued. This paper enumerates all major local PWV measurement methods while pinpointing their salient methodological considerations and emphasizing the necessity of global standardization. Further, a summary of the advancements in measuring modalities and clinical applications is provided. Additionally, a detailed discussion on the minimally explored concept of incremental local PWV is presented along with suggestions of future research questions.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Thin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Jian Li,Huiling Jia,Jingkun Zhou,Xingcan Huang,Long Xu,Shengxin Jia,Zhan Gao,Kuanming Yao,Dengfeng Li,Binbin Zhang,Yiming Liu,Ya Huang,Yue Hu,Guang Yao Zhao,Zitong Xu,Jiyu Li,C. Yiu,Yuyu Gao,Mengge Wu,Yanli Jiao,Qiang Zhang,Xue Cheng Tai,Raymond H Chan,Yuanting Zhang,Xiao Hui Ma,Xinge Yu +25 more
TL;DR: A thin, soft, miniaturized system that combines a conformal piezoelectric sensor array, an active pressure adaptation unit, a signal processing module, and an advanced machine learning method to allow real wearable, continuous wireless monitoring of ambulatory artery BP is reported.
100
A review of machine learning in hypertension detection and blood pressure estimation based on clinical and physiological data
TL;DR: In this paper, the authors present a literature review on the use of machine learning techniques in high blood pressure studies following two approaches: hypertension stage classification based on clinical data and blood pressure estimation based on related physiological signals.
82
Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models
TL;DR: In this article , the authors discuss the need for more complete calibration models and elaboration of continuous calibration procedures, independent of recalibration measurement, is the key to improving the accuracy and robustness of noninvasive continuous blood pressure estimation.
46
Assessment of Carotid Arterial Stiffness in Community Settings With ARTSENS
Jayaraj Joseph,P M Nabeel,Sudha Ramachandra Rao,Ramachandran Venkatachalam,Malay Ilesh Shah,Prabhdeep Kaur +5 more
TL;DR: The association of carotid stiffness with age, gender, hypertension/diabetes, smoking, and clustering of risk factors was studied and the trend persisted even after excluding hypertensives and subjects with diabetes.
Non-Invasive Methods for PWV Measurement in Blood Vessel Stiffness Assessment
TL;DR: In this article , the main commercially available devices underlining their operating principles in terms of sensors, execution mode, pulse waveforms acquired, site of measurement, distance and time estimation methods, as well as their main limitations in clinical practice.
39
References
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Chihiro Kasai,Koroku Namekawa,Akimitsu Harada +2 more
- 01 Jan 1986
TL;DR: In the system blood flow within a given cross section of a live organ is displayed in real time and the direction of blood Row and its variance are expressed by means of a difference in color and its hue, respectively.
1.1K
Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential Hypertension
Stéphane Laurent,Sandrine Katsahian,Céline Fassot,Anne-Isabelle Tropeano,Isabelle Gautier,Brigitte Laloux,Pierre Boutouyrie +6 more
TL;DR: This study provides the first evidence, in a longitudinal study, that aortic stiffness is an independent predictor of fatal stroke in patients with essential hypertension.
1.1K
Aortic input impedance in normal man: relationship to pressure wave forms.
TL;DR: The results suggest that the differences in pressure wave forms are due to differences in reflections in the arterial tree and not secondary to Differences in cardiac function.
1K
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
C. Kasai,K. Namekawa,A. Koyano,Ryozo Omoto +3 more
- 01 May 1985
TL;DR: In this paper, a new blood row imaging system is described that com- bines a conventional pulsed Doppler device and a newly developed AU-to-correlator, in which the direction of blood Row and its variance are expressed by means of a difference in color and its hue, respectively.
1K
Ultrafast imaging in biomedical ultrasound
Mickael Tanter,Mathias Fink +1 more
TL;DR: In this article, the basic principles and implementation of ultrafast imaging in biomedical ultrasound are illustrated and discussed in particular, present and future applications of ultra-fast imaging for screening, diagnosis, and therapeutic monitoring.
927
Related Papers (5)
[...]