Hand-Eye Calibration Using Dual Quaternions
TL;DR: This paper algebraically prove that if the authors consider the camera and motor transformations as screws, then only the line coefficients of the screw axes are relevant regarding the hand-eye calibration, and shows how a line transformation can be written with the dual-quaternion product.
read more
Abstract: To relate measurements made by a sensor mounted on a mechanical link to the robot’s coordinate frame, we must first estimate the transformation between these two frames. Many algorithms have been p...
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Robotic grasp detection based on image processing and random forest
TL;DR: This paper proposes a very quick and accurate approach to detect robotic grasps by developing a morphological image processing method to generate candidate grasp rectangles set which avoids us to search grasp Rectangles globally.
Minimally Invasive Holographic Surface Scanning for Soft-Tissue Image Registration
TL;DR: A system based on conoscopic holography that is capable of minimally invasive surface scanning and suitable for use with biological tissues is described, and can provide surface scans of comparable quality to existing clinically used laser range scanning systems that require open surgery.
Patent
Real-time generation of three-dimensional ultrasound image using a two-dimensional ultrasound transducer in a robotic system
Gary S. Guthart,David S. Mintz,Gunter Niemeyer,J. Kenneth Salisbury,Robert G. Younge +4 more
- 21 Aug 2013
TL;DR: In this paper, the authors present a system for performing robotically assisted surgical procedures on a patient, which enables an operator to selectively access and reference auxiliary information on the image display device during the performance of a surgical procedure.
48
Patent
Application of force feedback on an input device to urge its operator to command an articulated instrument to a preferred pose
Nicola Diolaiti,Paul E. Lilagan +1 more
- 09 Nov 2012
TL;DR: In this paper, a controller is configured to command manipulation an articulated instrument in response to operator manipulation of an associated input device while generating a force command to the input device that nudges the operator to command the instrument to a preferred pose.
48
Simultaneous robot-world and hand-eye calibration by the alternative linear programming
TL;DR: Both formulations provide new insights into the behavior and complexity of the simultaneous RW&HY calibration.
48
References
A new technique for fully autonomous and efficient 3D robotics hand/eye calibration
Roger Y. Tsai,R.K. Lenz +1 more
- 01 Jun 1989
TL;DR: In this article, the authors describe a technique for computing position and orientation of a camera relative to the last joint of a robot manipulator in an eye-on-hand configuration, which takes only about 100+64N arithmetic operations to compute the hand/eye relationship after the robot finishes the movement, and incurs only additional 64 arithmetic operations for each additional station.
1.4K
•Proceedings Article
A new technique for fully autonomous and efficient 3D robotics hand-eye calibration
Roger Y. Tsai,R.K. Lenz +1 more
- 01 May 1988
TL;DR: A novel technique for computing position and orientation of a camera relative to the last joint of a robot manipulator in an eye-on-hand configuration aimed at simplicity, efficiency, and accuracy while giving ample geometric and algebraic insights is described.
900
Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form AX=XB
Yiu Cheung Shiu,S. Ahmad +1 more
- 01 Feb 1989
TL;DR: Etalonnage d'un capteur monte sur le poignet d' un robot par resolutions des equations des transformations homogenes de la forme AX=XB.
Hand-eye calibration
Radu Horaud,Fadi Dornaika +1 more
TL;DR: A common mathematical framework is developed to solve for the hand-eye calibration problem using either of the two formulations and the nonlinear optimization method, which solves for rotation and translation simultaneously, seems to be the most robust one with respect to noise and measurement errors.