Early post-stress decrease in cardiac performance by impedance cardiography and its relationship to the severity and extent of ischemia by myocardial perfusion imaging
TL;DR: The data suggest that immediate post-stress changes in several hemodynamic parameters, detected by the NICaS, can be used as an important adjunct to SPECT MPI for the early detection of myocardial ischemia.
read more
Abstract: While single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a well-established noninvasive procedure for the evaluation of patients with coronary artery disease (CAD), it is unable to detect the presence of, or underestimates the extent of CAD in certain patients. We aimed to show that a bio-impedance device can detect early post-stress changes in several hemodynamic parameters, thereby serving as a potential marker for the presence of significant ischemia. Prospectively enrolled patients, referred to our Medical Center for clinically-indicated MPI, underwent testing using a Non-Invasive Cardiac System (NICaS) before and immediately after exercise. The differences between rest and stress hemodynamic parameters were compared with the severity and extent of myocardial ischemia by MPI. The study included 198 patients; mean age was 62 years, 26% were women, 54% had hypertension, and 29% diabetes mellitus. Of them, 188 patients had ≤10%, and 10 had > 10% of myocardial ischemia. In the first group, there was a significantly greater increase in post-exercise stroke index, stroke work index, cardiac index and cardiac power index (19.2, 29.1, 90.5 and 107%, respectively) compared with the second group (− 2.7, 3.8, 43.7 and 53.5%, respectively), as well as a significantly greater decrease in total peripheral resistance index (− 38.7% compared with − 16.3%), with corresponding p values of 0.015, 0.017, 0.040, 0.016, and < 0.001, respectively. Our data suggest that immediate post-stress changes in several hemodynamic parameters, detected by the NICaS, can be used as an important adjunct to SPECT MPI for the early detection of myocardial ischemia.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Cardiopulmonary exercise testing and impedance cardiography in the assessment of exercise capacity of patients with coronary artery disease early after myocardial revascularization
Günther Wüsten
- 17 Jul 2022
TL;DR: In this article , the authors evaluated the relationship between parameters of exercise capacity assessed via cardiopulmonary exercise testing (CPET) and impedance cardiography (ICG) hemodynamics in patients with coronary artery disease.
No improvement of physical capacity during cardiac rehabilitation in a patient with elevated IGF-1 and normal pressure hydrocephalus
Zuzanna Janicka,Małgorzata Kurpaska,Katarzyna Piotrowicz,Marzena Kubiak,Paweł Krzesiński +4 more
TL;DR: Rehabilitation kardiologicznej pacjenta z przewlekłym zespołem wieńcowym wymaga wdrożenia jak najszybkiego programu rehabilitacji po interwencji.
Whole-Body Impedance Cardiography-Derived Haemodynamic Parameters Associated With Outcomes in Clinically Stable Heart Failure Patients With Reduced Ejection Fraction
Emelissa J Valcourt,Olivia Pieroni,Hilary Bews,Aleksander Dokollari,Anita Soni,Shelley Zieroth,Ashish H Shah,Emelissa J Valcourt,Olivia Pieroni,Hilary Bews,Aleksander Dokollari,Anita Soni,Shelley Zieroth,Ashish H Shah +13 more
References
Single photon-emission computed tomography
Thomas A. Holly,Brian G. Abbott,Mouaz H. Al-Mallah,Dennis A. Calnon,Mylan C. Cohen,Frank P. DiFilippo,Edward P. Ficaro,Michael R. Freeman,Robert C. Hendel,Diwakar Jain,Scott Leonard,Kenneth Nichols,Donna M. Polk,Prem Soman +13 more
TL;DR: The current document is an update of an earlier version of single photon emission tomography guidelines that was developed by the American Society of Nuclear Cardiology, and should not be used in clinical studies until they have been reviewed and approved by qualified physicians and technologists from their own particular institutions.
648
Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel coronary artery disease.
Ronaldo de Souza Leão Lima,Denny D. Watson,Allen R. Goode,Mir S. Siadaty,Michael Ragosta,George A. Beller,Habib Samady +6 more
TL;DR: Adjunctive assessment of function with perfusion by gated SPECT MPI enhances the detection of defects in multiple vascular territories in patients with severe 3VD, without adversely affecting its specificity.
438
Adenosine versus regadenoson comparative evaluation in myocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trial.
Ami E. Iskandrian,Timothy M. Bateman,Luiz Belardinelli,Brent Blackburn,Manuel D. Cerqueira,Robert C. Hendel,Hsiao Lieu,John J. Mahmarian,Ann Olmsted,S. Richard Underwood,João V. Vitola,Whedy Wang +11 more
TL;DR: This phase 3 trial shows that regadenoson provides diagnostic information comparable to a standard adenosine infusion, and there were no serious drug-related side effects, and regadenoon was better tolerated than adenoine.
344
Underestimation of extent of ischemia by gated SPECT myocardial perfusion imaging in patients with left main coronary artery disease
Daniel S. Berman,Xingping Kang,Piotr J. Slomka,James Gerlach,Ling De Yang,Sean W. Hayes,John D. Friedman,Louise Thomson,Guido Germano +8 more
TL;DR: Assessment of perfusion data alone by visual or quantitative SPECT MPI analysis underestimates the magnitude of left main coronary artery disease, and the combination of perfusions and nonperfusion abnormalities on gated MPI identifies high risk in most patients with left main CAD.
344
High-Speed Myocardial Perfusion Imaging: Initial Clinical Comparison With Conventional Dual Detector Anger Camera Imaging
Tali Sharir,Simona Ben-Haim,Konstantine Merzon,Vitali Prochorov,Dalia Dickman,Shlomo Ben-Haim,Daniel S. Berman +6 more
TL;DR: High-speed SPECT provides fast MPI with high image quality and up to 8 times increased system sensitivity, and the amount of perfusion abnormality visualized by high- Speed SPECT is highly correlated to conventional SPECT, with an equivalent level of diagnostic confidence.
234
Related Papers (5)
Leslee J. Shaw,Daniel S. Berman,Michael H. Picard,Matthias G. Friedrich,Raymond Y. Kwong,Gregg W. Stone,Roxy Senior,James K. Min,Rory Hachamovitch,Marielle Scherrer-Crosbie,Jennifer H. Mieres,Thomas H. Marwick,Lawrence M. Phillips,Farooq A. Chaudhry,Patricia A. Pellikka,Piotr J. Slomka,Andrew E. Arai,Ami E. Iskandrian,Timothy M. Bateman,Gary V. Heller,Todd D. Miller,Eike Nagel,Abhinav Goyal,Salvador Borges-Neto,William E. Boden,Harmony R. Reynolds,Judith S. Hochman,David J. Maron,Pamela S. Douglas +28 more