Journal Article10.1007/s00330-022-09294-1
Diffusion-weighted MRI with deep learning for visualizing treatment results of MR-guided HIFU ablation of uterine fibroids
D. J. Slotman,Lambertus W. Bartels,Aylene Zijlstra,Inez M Verpalen,Jochen A. C. van Osch,Ingrid M. Nijholt,Edwin Heijman,Miranda van 't Veer-Ten Kate,Erwin de Boer,R. D. van den Hoed,Martijn Froeling,Martijn F. Boomsma +11 more
8
TL;DR: Deep learning–based synthetic CE-T1w scans derived from intraprocedural DWI allow gadolinium-free visualization of the predicted NPV, and can potentially be used for repeated gadolinium-free monitoring of treatment progression during MR-HIFU therapy for uterine fibroids.
read more
About: This article is published in European Radiology. The article was published on 06 Dec 2022. The article focuses on the topics: Medicine & Medicine.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
Use of Diode Laser in Hysteroscopy for the Management of Intrauterine Pathology: A Systematic Review
A Etrusco,Giovanni Buzzaccarini,Antonio Simone Laganà,Vito Chiantera,Salvatore Giovanni Vitale,Stefano Angioni,Maurizio Nicola D'Alterio,Luigi Nappi,Felice Sorrentino,Amerigo Vitagliano,Tommaso Difonzo,Gaetano Riemma,Liliana Mereu,Alessandro Favilli,Panagiotis Peitsidis,Antonio D’Amato +15 more
TL;DR: Diode laser through “see and treat” hysteroscopy appears to be a safe and effective method, however, additional studies with larger sample sizes and improved designs are needed to consolidate the evidence currently available in the literature.
13
No incision required for long-lasting symptom relief in a selection of women suffering from uterine fibroids.
D.J. Slotman,Ingrid M. Nijholt,Joke M. Schutte,Martijn F. Boomsma +3 more
TL;DR: MRI-guided focused ultrasound (MRgFUS) offers an excellent non-invasive uterus-sparing treatment option for a selection of women with symptomatic uterine fibroids and aligns perfectly with several of radiology's and gynecology’s missions for the future.
2
Diffusion-weighted imaging as a potential non-gadolinium alternative for immediate assessing the hyperacute outcome of MRgFUS ablation for uterine fibroids
Yaoqu Huang,Shangcheng Zhou,Yuhua Su,Zhuochao Pang,Shengbao Cai +4 more
TL;DR: DWI can effectively assess the hyperacute outcome of MRgFUS ablation for uterine fibroids, providing a non-gadolinium alternative for immediate evaluation.
1
Intravoxel incoherent motion (IVIM)-derived perfusion fraction mapping for the visual evaluation of MR-guided high intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids.
D.J. Slotman,Lambertus W. Bartels,Ingrid M. Nijholt,Martijn Froeling,Judith A F Huirne,C. Moonen,Martijn F Boomsma +6 more
TL;DR: The MR-HIFU treatment effect in uterine fibroids can be visualized using IVIM perfusion fraction mapping, in moderate concordance with contrast enhanced MRI, and has the potential to serve as a contrast agent-free imaging method to visualize the MR-HIFU treatment progression in uterine fibroids.
1
Advancements in deep learning for image-guided tumor ablation therapies: a comprehensive review
Ziqi Zhao,Yibo Hu,Lisa X. Xu,Jianqi Sun +3 more
TL;DR: This comprehensive review explores the advancements of deep learning in image-guided tumor ablation therapies, highlighting its potential to enhance precision, safety, and efficacy in preoperative planning, intraoperative navigation, and postoperative monitoring.
References
Systematic review and meta-analysis
TL;DR: In this review the usual methods applied in systematic reviews and meta-analyses are outlined, and the most common procedures for combining studies with binary outcomes are described, illustrating how they can be done using Stata commands.
34.9K
elastix : A Toolbox for Intensity-Based Medical Image Registration
TL;DR: The software consists of a collection of algorithms that are commonly used to solve medical image registration problems, and allows the user to quickly configure, test, and compare different registration methods for a specific application.
4.3K
Checklist for Artificial Intelligence in Medical Imaging (CLAIM): A Guide for Authors and Reviewers.
John Mongan,Linda Moy,Charles E. Kahn +2 more
- 25 Mar 2020
TL;DR: 1.2 Structured summary of study design, methods, results, and conclusions.
917
Clinical Intravoxel Incoherent Motion and Diffusion MR Imaging: Past, Present, and Future.
Mami Iima,Denis Le Bihan +1 more
TL;DR: A review of the clinical literature, mainly focusing on current outstanding issues, is given, followed by some innovative proposals for future improvements.
456
The capillary network: a link between ivim and classical perfusion
Le Bihan D,Robert Turner +1 more
TL;DR: This note shows that the knowledge of the capillary network organization may provide a link between these measurements and those obtained by conventional and MR perfusion techniques based on tracer uptake by tissues.