Journal Article10.1021/AC00298A029
Deconvolution of overlapping chromatographic peaks
67
TL;DR: In this paper, the methode de deconvolution basee on l'analyse factorielle des spectres de melanges d'eluants de chromatographie en phase gazeuse/spectrometrie de masse is used.
read more
Abstract: Exemples d'applications de la methode de deconvolution basee sur l'analyse factorielle des spectres de melanges d'eluants de chromatographie en phase gazeuse/spectrometrie de masse, chromatographie en phase liquide/spectrometre visible-UV, chromatographie en phase gazeuse/spectrometrie IR a transformee de Fourier
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
An experimental study of the efficiency of different statistical functions for the resolution of chromatograms with overlapping peaks
TL;DR: The results obtained in the curve fitting of individual peaks, corresponding to diverse solutes run in polar, semi-polar and apolar columns, show that the log-normal function is generally the best for description of the chromatographic shapes.
13
Theory of evolutionary factor analysis for resolution of ternary mixtures
TL;DR: In this paper, a self-modeling approach for the resolution of quaternary mixtures is developed from explicit theoretical principles, and the SEPARATOR algorithm is extended to quaternaries plus mixtures.
13
Reliability of factor analysis in the presence of random noise or outlying data
TL;DR: A Monte Carlo study of the effect of random error in data from NMR and GC-MS experiments indicates that the eigenvalue ratio test and Malinowski's indicator function are more accurate that the imbedded error function in determining the number of significant factors or components.
12
Evaluation of the effect of polymorphism on G-quadruplex-ligand interaction by means of spectroscopic and chromatographic techniques
TL;DR: The ligand was shown to interact preferentially with the monomeric G-quadruplex; the binding stoichiometry was 1:1 and the binding constant was in the order of 105M-1 for all three sequences, highlighting the importance of DNA treatment prior to interaction studies.
Resolution of overlapping peaks in gas and liquid chromatography
TL;DR: In this paper, the effectiveness of different statistical distribution functions (Gaussian, log-normal, gamma and Weibull) was examined for the deconvolution of chromatograms with overlapping peaks generated under diverse instrumental set-ups and operating conditions.
11
References
Self Modeling Curve Resolution
TL;DR: In this paper, a method for determining the shapes of two overlapping functions f 1 (x) and f 2(x) from an observed set of additive mixtures is presented.
883