Journal Article10.1109/joe.2022.3220880
An Ultracompact Underwater Pulsed Digital Holographic Camera With Rapid Particle Image Extraction Suite
11
TL;DR: In this article , the authors presented the design, development, and testing of an ultracompact underwater pulsed digital holographic camera (named weeHoloCam) that has been successfully deployed in the North Sea.
read more
Abstract: This article presents the design, development, and testing of an ultracompact underwater pulsed digital holographic camera (named weeHoloCam) that has been successfully deployed in the North Sea. With a footprint of 9 cm diameter × 60 cm long and weighing just 3.5 kg, to our knowledge, this is the lightest and most compact system of its kind in the world. It can be easily adapted for mounting on remotely operated underwater vehicles (ROVs) and autonomous underwater vehicles (AUVs). weeHoloCam can record 12 cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> of the water column per hologram at 20 Hz and has a capacity to continuously record up to 200 000 holograms, each 5 MB in size. Along with the holographic camera, a field-programmable gate array (FPGA)-accelerated hologram analysis suite has been developed. The 838 megapixel/s reconstruction speed demonstrated is the highest reported speed for a single FPGA implementation to date. This is an extremely important development as rapid processing of recorded holograms is vital for the viability of subsea holographic cameras. weeHoloCam was successfully trialed in the North Sea, recording close to a hundred thousand holograms and extracting particle images within those holograms at a rate of 190 per min. weeHoloCam has the potential to play an important role in several oceanic studies: spatial and temporal monitoring of plankton species; study of plankton dynamics; study of vertical transport of floc; and monitoring microplastic pollution in the ocean, to name but a few.
read more
Chat with Paper
AI Agents for this Paper
Find similar papers on Google Scholar, PubMed and Arxiv
Write a critical review of this paper
Analyze citations of this paper to find unaddressed research gaps
Citations
In-situ detection of microplastics in the aquatic environment: A systematic literature review.
Ismaila Abimbola,Marion McAfee,Leo Creedon,Salem Gharbia +3 more
TL;DR: This systematic review assesses in-situ detection methods for aquatic microplastics, evaluating 62 studies across seven sensor categories, and concludes that in-situ detection is feasible with high accuracy, but further research is needed to enhance detection capabilities.
7
Advanced subsea imaging technique of digital holography: in situ measurement of marine microscale plankton and particles
06 Mar 2023
TL;DR: In this paper , the basic principles of in-line digital holography and common image processing methods for underwater holographic imaging systems are described, and some possible solutions are discussed.
2
Pushing the Frontiers of Micro/Nano-Plastic Detection with Portable Instruments
Yuhao Yan,Yuling Li,Jie Gao,Jun Cheng,Xuehan Zheng,Guangxuan Wang,Yun Ding,Jing Zhao,Hua Qin,Chao Zhao,Kathy Qian Luo,Runzeng Liu,Li‐Qun Chen,Zongwei Cai,Bing Yan,Guangbo Qu,Guibin Jiang +16 more
2
An Ultracompact Underwater Digital Holographic Camera for Study of Marine Microorganisms
Thangavel Thevar,Dafne Eerkes-Medrano,Nicholas Burns,Michael Ockwell,John Watson +4 more
- 05 Jun 2023
TL;DR: The design and development of weeHoloCam is presented and results from a number of its ocean deployments are presented, including those derived from the plankton images.
Monitoring Bioindication of Plankton through the Analysis of the Fourier Spectra of the Underwater Digital Holographic Sensor Data
Victor V. Dyomin,Alexandra Davydova,Nikolay Kirillov,O. Kondratova,Yuri N. Morgalev,Sergey Yu. Morgalev,T. G. Morgaleva,I. G. Polovtsev +7 more
- 08 Apr 2024
TL;DR: The research presents a novel bioindication system based on the analysis of the Fourier spectra of underwater digital holographic sensor data. The system enables the monitoring of plankton and its behavioral characteristics in situ, providing additional possibilities for studying the ecosystem well-being.
References
The Underwater Vision Profiler 5: An advanced instrument for high spatial resolution studies of particle size spectra and zooplankton
TL;DR: The Underwater Vision Profiler (UVP) was developed to quantify the vertical distribution of macroscopic particles and zooplankton 100 mu m in size.
Real-time digital holographic microscopy using the graphic processing unit
TL;DR: A real-time DHM system using a graphic processing unit (GPU) with many stream processors, which allows use as a highly parallel processor, and the computational speed of the Fresnel diffraction using the GPU is faster than that of recent CPUs.
196
A three-axis fast-tow digital Video Plankton Recorder for rapid surveys of plankton taxa and hydrography
TL;DR: A new Video Plankton Recorder (VPRII) has been developed for rapid surveys of plankton and seston in the size range of 100µm–1cm, which counts more plankton per station, quantifies ubiquitous fragile forms, automatically identifies plankton to major taxa and measures their size, and quantifies scales of patchiness down to a few cm.
163
A system for high-resolution zooplankton imaging
TL;DR: The mechanical, optical, and data processing design of this instrument is summarized and recent improvements are discussed and images and quantitative results from recent deployments in the Gulf of Mexico are presented.
121
Holographic Microscopy as a Technique for Recording Dynamic Microscopic Subjects
TL;DR: Holography, with submi crosecond pulsed lasers used for illumi nation, enables one to record an instant of time of a transient, dynamic event throughout a significant volume for later study and analysis with conventional microscopic equipment.
104
Related Papers (5)
16 Nov 2022