Peng Wang
Sichuan University
16 Papers
34 Citations
Peng Wang is an academic researcher from Sichuan University. The author has contributed to research in topics: Detector & Scattering. The author has an hindex of 5, co-authored 14 publications.
Chat about Author
Papers
An ion beam facility based on a 3 MV tandetron accelerator in Sichuan University, China
Jifeng Han,Zhu An,Gaoqun Zheng,Fan Bai,Zhihui Li,Peng Wang,Xiao-Dong Liao,Mantian Liu,Shunli Chen,Ming-Jiang Song,Jun Zhang +10 more
TL;DR: In this paper, a new ion beam facility based on a 3'MV tandetron accelerator system has been installed in Sichuan University, China, which demonstrates a great application potential in fields such as nuclear, material and environmental studies.
57
Patent
Single-source X-ray transmission and Compton scattering security check device in L-shaped structure
Zhou Yong,Huang Ning,Ding Houben,Zhu An,Wu Qingxing,Chen Xu,Wu Zhangwen,Deng Weicheng,Zhang Zhen,Peng Wang,Fan Yixiang,Li Caixiu +11 more
- 12 Jun 2013
TL;DR: In this article, a single-source X-ray transmission and Compton scattering security check device in an L-shaped structure is described, which is low in price, quick in detection speed, high in sensitivity, capable of detecting different types of prohibited goods such as metal weapons, explosive, and narcotics simultaneously.
8
Patent
Storage method for centralized extensible fusion type multi-dimensional complex structure relational data
Xia Xiang,Fan Yixiang,Huang Ning,Peng Wang +3 more
- 09 Nov 2016
TL;DR: In this paper, a storage method for centralized extensible fusion type multi-dimensional complex structure relational data is proposed, which is suitable for storing, analyzing and managing the large, medium and small-scale complex data of the enterprises, providing effective data with quality assurance for the user-oriented enterprise-level big data integration platforms, and providing an extensible and usable data storage and access technology.
6
An experimental system of wide-range two dimensional Rutherford backscattering analysis in vacuum chamber
TL;DR: In this article, a 2D moving sample stage in vacuum chamber is used to precisely position points to be analyzed in target, and synchronously starting spectrum acquisition when the sample stage is located at the measurement point and saving the corresponding spectrum when the acquisition is finished by utilizing the job control script of ORTEC MAESTRO software.
5
Patent
U-shaped unisource X-ray transmission and compton scattering safety inspection device
Zhou Yong,Huang Ning,Ding Houben,Zhu An,Wu Qingxin,Chen Xu,Wu Zhangwen,Deng Weicheng,Zhang Zhen,Peng Wang,Fan Yixiang,Li Caixiu +11 more
- 10 Apr 2013
TL;DR: In this article, a U-shaped unisource X-ray transmission and compton scattering safety inspection device is proposed. But the design of the detector array is not discussed.
4