M. Fioretto
Seconda Università degli Studi di Napoli
11 Papers
26 Citations
M. Fioretto is an academic researcher from Seconda Università degli Studi di Napoli. The author has contributed to research in topics: Power factor & Switched-mode power supply. The author has an hindex of 5, co-authored 11 publications.
Chat about Author
Papers
Power losses analysis in AC/DC conversion based on active front end systems
M. Fioretto,G. Raimondo,Luigi Rubino,N. Serbia,Pompeo Marino +4 more
- 14 Jun 2010
TL;DR: In this paper, a methodology for power losses analysis in active front end (AFE) converters based on VSI has been proposed and an analytical and numerical approach for losses evaluation have been proposed by the authors.
14
Considerations on boost inductor design in back-to-back converters for renewable energy
M. Fioretto,Philippe Ladoux,Pompeo Marino,G. Raimondo,Luigi Rubino,N. Serbia +5 more
- 14 Jun 2011
TL;DR: In this article, the converter inductor design in PWM back-to-back converter based on Synchronous Active Front End (SAFE) is discussed, and the design of the inductance is carried out evaluating an admissible range according to imposed power quality requirements and power rate desired.
13
Techniques of PWM space vector modulation for the reduction of magnetic acoustic noise in traction motor
L. Accardo,M. Fioretto,G. Giannini,Pompeo Marino +3 more
- 23 May 2006
TL;DR: In this paper, a mixed PWM random modulation (MPR) scheme was proposed for reducing magnetic-acoustic noise in asynchronous motors for railway traction, fed by an inverter.
12
Design criteria for AC link reactors in active front end converters for renewable energy applications in smart grids
M. Fioretto,Roberto Langella,G. Raimondo,G. Rubino,Luigi Rubino,N. Serbia,Alfredo Testa,Pompeo Marino +7 more
- 12 Nov 2012
TL;DR: In this paper, the AC link reactor of a Synchronous Active Front End (SAFE) system used as interface between a generic renewable energy source and the distribution grid is presented, and a variation range inside which the AC reactor value can be selected is proposed based on an analytic approach.
10
Evaluation of current harmonic distortion in wind farm application based on Synchronous Active Front End converters
M. Fioretto,G. Raimondo,Luigi Rubino,N. Serbia,Pompeo Marino +4 more
- 10 Nov 2011
TL;DR: In this article, the authors present a mathematical approach to estimate the harmonic distortion of converter current at the PCC due to SPWM modulation, showing the advantages in terms of current spectrum of the synchronous active front-end (SAFE) topology.
8