Gabriele Ansaldi
13 Papers
12 Citations
Gabriele Ansaldi is an academic researcher. The author has contributed to research in topics: Laser & Ranging. The author has an hindex of 4, co-authored 6 publications.
Chat about Author
Papers
Development of a hard X-ray split-and-delay line and performance simulations for two-color pump-probe experiments at the European XFEL
Wei Lu,Bernd Friedrich,T. Noll,Kangmin Zhou,Jörg Hallmann,Gabriele Ansaldi,Thomas Roth,Svitozar Serkez,Gianluca Geloni,Anders Madsen,Stefan Eisebitt +10 more
TL;DR: Simulations indicate that more than 109 photons on the sample per pulse-pair and up to about 10% photon energy separation can be achieved in the hard X-ray region using the SDL.
Materials Imaging and Dynamics (MID) instrument at the European X-ray Free-Electron Laser Facility.
Anders Madsen,Jörg Hallmann,Gabriele Ansaldi,Thomas Roth,Wei Lu,Chan Kim,Ulrike Boesenberg,Alexey Zozulya,Johannes Möller,R. Shayduk,Markus Scholz,A. Bartmann,A. Schmidt,I. Lobato,K. Sukharnikov,Mario Reiser,K. Kazarian,Ilia Petrov +17 more
TL;DR: The Materials Imaging and Dynamics (MID) instrument at the European X-ray Free-Electron Laser (EuXFEL) facility is described in this article, where the authors focus on studies of structure and dynamics in materials by coherent scattering and imaging using hard X-rays.
Operational experience with Adaptive Gain Integrating Pixel Detectors at European XFEL
J. Sztuk-Dambietz,Vratko Rovensky,Alexander Klujev,Torsten Laurus,U. Trunk,Karim Ahmed,Olivier Meyer,Johannes Möller,Andrea Parenti,Natascha Raab,R. Shayduk,M. Sikorski,Gabriele Ansaldi,Ulrike Bösenberg,Lopez M. Luis,Astrid Muenich,T. Preston,Philipp Schmidt,Stephan Stern,Richard Bean,Anders Madsen,Luca Gelisio,Steffen Hauf,Patrick Gessler,Krzysztof Wrona,Heinz Graafsma,M. Turcato +26 more
TL;DR: The AGIPD1M detectors at European XFEL have demonstrated high-quality scientific results over 6 years, with developed methodologies for characterization, calibration, and data correction, enabling optimized detector performance and highest quality experimental results.
2
The beam stop as an intensity monitor
Leonard Müller,Michael Walther,M. Riepp,Andre Philippi-Kobs,Wisam Jo,Wojciech Roseker,Kai Bagschik,Robert Frömter,Rui Pan,D. Lott,Johannes Möller,Ulrike Bösenberg,Jörg Hallmann,Angel Rodriguez-Fernandez,Markus Scholz,Gabriele Ansaldi,J. Wrigley,A. Zozulya,Anders Madsen,Gerhard Grübel +19 more
TL;DR: In this article , the integral intensity of the FEL beam transmitted through the sample can be measured by photodiodes providing a proper normalization of measurement data, which can be seen as a solution to the problem of pointing instability.
1